Zero Air Gas Generator (without Air Compressor) - Model : ZA-10L

Zero Air Gas Generator (without Air Compressor) - Model : ZA-10L

248600 INR/Number

Product Details:

  • Model No ZA-10L
  • Automation Grade Automatic
  • Measurement Range Hydrocarbon Content <0.1 ppm
  • Frequency 50 Hz
  • Power Source Electric
  • Feature Removes Hydrocarbons to <0.1 ppm
  • Capacity 10 Liters/Min
  • Click to View more
X

Zero Air Gas Generator (without Air Compressor) - Model : ZA-10L Price And Quantity

  • 248600 INR/Number
  • 1 Number
  • Clean Dry Air
  • 99.999% (Zero Air)
  • 4 to 6 bar
  • Low, Easy Service Access
  • Microprocessor Based
  • Suitable for GC, TOC Analyzers, Environmental Lab Use
  • Table Top
  • <35 dB
  • 1/4" BSP
  • Adjustable
  • CE Certified
  • Air Cooled
  • Up to 85% RH
  • Over-temperature Protection, Pressure Relief Valve

Zero Air Gas Generator (without Air Compressor) - Model : ZA-10L Product Specifications

  • Catalyst, Heating System, Control Panel
  • 230V AC
  • 10 Liters/Min
  • Laboratory/Analytical Instruments
  • Hydrocarbon Removal Efficiency >99.9%
  • LED Display
  • Ambient to 50C
  • 45 x 30 x 45 cm
  • 20 kg (Approx)
  • Hydrocarbon Content <0.1 ppm
  • Automatic
  • Stainless Steel
  • Zero Air Gas Generator (without Air Compressor)
  • ZA-10L
  • Removes Hydrocarbons to <0.1 ppm
  • 50 Hz
  • Electric
  • Clean Dry Air
  • 99.999% (Zero Air)
  • 4 to 6 bar
  • Low, Easy Service Access
  • Microprocessor Based
  • Suitable for GC, TOC Analyzers, Environmental Lab Use
  • Table Top
  • <35 dB
  • 1/4" BSP
  • Adjustable
  • CE Certified
  • Air Cooled
  • Up to 85% RH
  • Over-temperature Protection, Pressure Relief Valve

Product Description

Zero Air Gas Generator (without Air Compressor) - Model: ZA-10L is intended to accept compressed air from either an internal or external compressor. The oil-free compressor sends air via a high-efficiency coalescing input filter, which traps moisture that may harm the system. This lowers background noise and improves the sensitivity of your analyses. Zero Air Gas Generator (without Air Compressor) - Model: ZA-10L is used to prevent any form of particle from entering the analytical equipment, and an output particle filter is utilized. This is used to provide clean, dry, hydrocarbon-free air.

 



Advanced Purity for Laboratory Applications

The ZA-10L Zero Air Gas Generator ensures consistent delivery of ultra-pure air with hydrocarbon content below 0.1 ppm, making it an ideal choice for sensitive laboratory instruments such as gas chromatographs and TOC analyzers. Its microprocessor-based control and easy LED display allow for precise monitoring, while the air-cooled stainless-steel construction provides durability and reliability in demanding environments.


Efficient Operation and Safety Assured

Designed with laboratory convenience in mind, the ZA-10L operates at a whisper-quiet level and features advanced safety mechanisms, including over-temperature protection and a pressure relief valve. It offers low-maintenance operation and straightforward service access, ensuring minimal downtime and trouble-free usage, all while remaining CE compliant.

FAQ's of Zero Air Gas Generator (without Air Compressor) - Model : ZA-10L:


Q: How does the Zero Air Gas Generator ZA-10L achieve such high purity levels?

A: The ZA-10L utilizes a high-efficiency catalyst and precision heating system to remove hydrocarbons down to less than 0.1 ppm, delivering 99.999% pure zero air for laboratory applications.

Q: What is the process for starting up and operating the ZA-10L Generator?

A: To operate the ZA-10L, connect it to a supply of clean, dry air (using the 1/4" BSP connection), set your desired flow rate via the adjustable controls, then power on the unit. The microprocessor-based control system automatically manages operation and maintains optimal conditions.

Q: When should I perform maintenance on this generator, and what does it involve?

A: The ZA-10L is designed for low maintenance. Routine checks include ensuring the inlet air remains clean and periodically inspecting core components. Easy service access is provided for swift, hassle-free maintenance.

Q: Where can the ZA-10L be installed, and what are the space requirements?

A: This generator is compact and intended for simple table-top installation. Requiring just 45 x 30 x 45 cm of space, it is suitable for most laboratory environments where space efficiency and accessibility are priorities.

Q: What are the benefits of using the ZA-10L without an integrated air compressor?

A: By operating without an internal compressor, the ZA-10L stays quieter (<35 dB), requires less maintenance, and allows you to utilize an existing source of clean, dry air. This design enhances overall reliability and reduces operational noise.

Q: How does the control system enhance user experience and safety?

A: The microprocessor-based control and LED display offer easy monitoring, while built-in safety features-such as over-temperature protection and a pressure relief valve-ensure safe, reliable operation at all times.