Product Details:

  • Measurement Range 0 9999 ppm
  • Temperature Range 0C to 60C
  • Feature Auto Temperature Compensation (ATC), Low Battery Indicator
  • Accuracy 2% of reading
  • Power Source 2 x 1.5V AAA Batteries
  • Automation Grade Automatic
  • Frequency 50/60 Hz
  • Click to View more
X

TDS Analyzer Product Specifications

  • 0 9999 ppm
  • Auto Temperature Compensation (ATC), Low Battery Indicator
  • 0C to 60C
  • Determines Total Dissolved Solids in liquids
  • 2% of reading
  • 2 x 1.5V AAA Batteries
  • Digital LCD Display
  • ABS Plastic Body; Stainless Steel Electrodes
  • 50/60 Hz
  • Automatic
  • Approx 200 g
  • 3V DC
  • Stated as 50 ml sample holder capacity
  • 180 x 30 x 20 mm
  • TDS Sensor, Microcontroller, Display Unit

Product Description

Backed with a team of experienced professionals, we are offering our valuable clients a wide range of TDS Analyzer. This product range is manufactured in our high-end fabrication unit under the strict inspection of quality instructors using the finest quality factor inputs to ensure flawlessness. The offered ConCal10 is prized for its sturdy construction, optimum performance and reliable functionality. The offered product is supplied with conductivity cell K= 1.0, temperature probe, electrode stand with clamp, dust cover, DC adaptor, operational & instruction manual, manufacturer test certificate and warranty card.

Technical Specification
  • Conductivity Range : 0 to 20.00, 200.0, 2000 S/Cm; 2 to 20.00, 200.0 ms/cm
  • Conductivity Resolution : 0.001,0.01,0.1 S/cm & 0.01, 0.001 mS/cm
  • TDS Range : 0 to 10.00, 100.0, 1000 ppm; 10.00, 100.0 ppt(1ppt=10,000ppm)
  • TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01ppt
  • Range Selection : Auto / Manual Ranging
  • Temperature Range : 0 to 130.0oC
  • Temperature Resolution : 0.1oC
  • Temp. Compensation : Automatic & Manual
  • Temperature Coefficient : 0-10.000 % per oC
  • (Adjustable) Suitable Cell Constant : 0.1, 0.5, 1.0 K
  • Adjustable Cell Constant : 0.09 to 1.1 K
  • Cond. to TDS Conv. Fac. : 0.40000 to 1.00000 (Adjustable)
  • Backlit LCD Display : 16 x 2 line Alphanumeric
  • Printer Capability : Yes - Parallel Port
  • Power Requirement : DC Adapter

Salient Features

  • Auto Ranging
  • Scrolling Display of Conductivity at 25oC
  • Conductivity at actual Temperature & TDS
  • Auto / Manual Temperature Compensation
  • Last Calibration Data storage with date and reading
  • Current Analysis Data Printing Facility with Calibration data
  • 10 analysis data storage with corresponding Calibration data etc.

Error Message

  • Bad Cell / Standard
  • Temperature Probe
  • Range Suggestion, in Manual Mode


Advanced Measurement Technology

Utilizing a state-of-the-art TDS sensor, this analyzer delivers accurate measurements of dissolved solids in any liquid sample. The automatic temperature compensation (ATC) feature ensures that readings are reliable across a wide temperature range. Its digital LCD display presents the results clearly and instantly, simplifying data interpretation for users.


Built to Last and Easy to Use

Constructed with a sturdy ABS plastic body and durable stainless steel electrodes, the TDS Analyzer is engineered for longevity and consistent performance. Its ergonomic design, combined with an automatic operation mode, makes the device user-friendlyideal for frequent testings in laboratories, industrial settings, and field use.

FAQs of TDS Analyzer:


Q: How does the TDS Analyzer determine the total dissolved solids in liquids?

A: The device uses stainless steel electrodes to measure electrical conductivity, which is then processed by the microcontroller to calculate the concentration of total dissolved solids (TDS) in parts per million (ppm).

Q: What is the process for operating the TDS Analyzer?

A: Simply fill the 50 ml sample holder with your liquid, turn on the device, and allow the automatic sensor to analyze the sample. The result will be displayed on the digital LCD screen within moments.

Q: Where can the TDS Analyzer be used effectively?

A: It is suitable for use in laboratories, water treatment facilities, industrial plants, and by exporters and suppliers who need quick and dependable TDS measurements.

Q: When should I replace the batteries in the TDS Analyzer?

A: The device is equipped with a low battery indicator on the LCD display, alerting you when it is time to replace the two 1.5V AAA batteries.

Q: What are the benefits of the Auto Temperature Compensation (ATC) feature?

A: The ATC feature automatically adjusts the TDS reading based on the samples temperature, ensuring accuracy between 0C to 60C, regardless of environmental changes.

Q: How accurate are the TDS measurements with this analyzer?

A: The analyzer provides results with an accuracy of 2% of the reading, offering reliable data for most laboratory and industrial requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Chemical Testing Instruments - Conductivity Meter' category