Back to top
Tablet Disintegration Test Apparatus (Independent Motor and Timer for Two Basket) - Model : TDTCal50

Tablet Disintegration Test Apparatus (Independent Motor and Timer for Two Basket) - Model : TDTCal50

185600 INR/Number

Product Details:

  • Automation Grade Semi-Automatic
  • Model No TDTCal50
  • Core Components Independent Motors, Timer, Control Panel, Heaters, Baskets
  • Feature Independent Motor & Timer for each basket
  • Power Source 230 V AC, 50 Hz
  • Measurement Range Disintegration time measurement up to 99 minutes
  • Capacity 2 Testing Stations (Dual Baskets)
  • Click to View more
X

Tablet Disintegration Test Apparatus (Independent Motor and Timer for Two Basket) - Model : TDTCal50 Price And Quantity

  • 185600 INR/Number
  • 1 Number

Tablet Disintegration Test Apparatus (Independent Motor and Timer for Two Basket) - Model : TDTCal50 Product Specifications

  • Stainless Steel (SS 304) with acrylic water bath
  • Ambient to 45°C
  • 230 V
  • 2 Testing Stations (Dual Baskets)
  • ±0.5°C
  • 50 Hz
  • Approx. 25 kg
  • 470 mm x 310 mm x 350 mm
  • Digital LED Display
  • Semi-Automatic
  • Disintegration time measurement up to 99 minutes
  • 230 V AC, 50 Hz
  • Independent Motor & Timer for each basket
  • Independent Motors, Timer, Control Panel, Heaters, Baskets
  • TDTCal50
  • Pharmaceutical laboratory testing of tablet disintegration
  • Laboratory Tablet Disintegration Test Apparatus

Product Description



Experience exclusive precision with the Latest Tablet Disintegration Test Apparatus (Model: TDTCal50)engineered for pharmaceutical laboratories demanding unrivaled accuracy. Equipped with independent motors and timers for its dual baskets, this remarkable apparatus utilizes a microprocessor-controlled heating system, ensuring excellent temperature uniformity (0.5C) with PT100 sensor feedback. Certified calibration traceable to NIST standards ensures trust and reliability. Crafted from durable stainless steel with an acrylic water bath, it boasts digital LED displays, presettable timers, and robust safety features. Limited stocksecure this advantage for compliant, consistent, and efficient testing.

Unmatched Precision and Versatility

Used by pharmaceutical laboratories, the TDTCal50 delivers precise tablet disintegration analysis with independent dual basket movement and individual timers. Its additional features include digital LED display, superior overheating protection, and a certified calibration process, ensuring consistent results. Competitive advantages include its remarkable compliance with global standards (USP, BP, IP), NIST-traceable calibration, and robust construction with SS 304 and acrylic componentsmaking it a trusted, long-lasting choice for rigorous laboratory environments.


Available NowFast Shipping and Reliable Supply

Sample units of the TDTCal50 are available for quality evaluation. Benefit from our express shipping and reliable order completion service for both domestic and international markets. With an impressive monthly supply ability, customers receive secure, protective packaging to prevent damage during transit. From packaging to doorstep delivery, each unit is handled with the utmost careensuring every limited-stock apparatus arrives ready for immediate integration into your laboratory workflow.


FAQs of Tablet Disintegration Test Apparatus (Independent Motor and Timer for Two Basket) - Model : TDTCal50:


Q: How does the independent motor and timer feature enhance testing accuracy?

A: Each basket in the TDTCal50 operates with its own dedicated motor and timer, allowing separate, precise control over disintegration testing parameters for two samples simultaneously. This independent operation minimizes cross-interference and delivers highly accurate, repeatable results.

Q: What is the process for calibrating the Tablet Disintegration Test Apparatus?

A: The TDTCal50 comes factory calibrated with certification traceable to NIST standards. For ongoing calibration, users can follow the guidelines provided in the manualensuring equipment maintains compliance with USP, BP, and IP standards.

Q: Where can this apparatus be used most effectively?

A: The TDTCal50 is designed primarily for use in pharmaceutical laboratories, research centers, and quality control environments where precise tablet disintegration testing is vital to meeting global compliance requirements.

Q: What safety features are included in the TDTCal50?

A: This apparatus is equipped with over-temperature protection and a buzzer alert system. These features safeguard both users and samples by promptly addressing any potentially hazardous conditions during operation.

Q: What are the main benefits of choosing this model over standard equipment?

A: The TDTCal50 offers dual independent operation, certified calibration, robust stainless steel and acrylic build, and an unrivaled accuracy of 0.5C. These advantages ensure superior reliability, compliance, and operational efficiency for high-throughput laboratories.