Back to top
Tablet Disintegration Test Apparatus

Tablet Disintegration Test Apparatus

284800.0 INR/Number

Product Details:

  • Model No TDA-01
  • Accuracy 0.5 C (temperature), 1 sec (timer) C
  • Core Components Heater, glass beaker, basket assembly, motor, timer, temperature controller
  • Frequency 50 Hz Hertz (HZ)
  • Capacity 2 baskets (simultaneous test) or 6 tubes per basket Pcs/hr
  • Temperature Range Ambient to 45 C ( 0.5 C) Celsius (oC)
  • Power Source Electric
  • Click to View more
X

Tablet Disintegration Test Apparatus Price And Quantity

  • 1 Number
  • 284800.0 INR/Number
  • Single or dual station configuration available
  • Operating temperature 1040C, non-condensing
  • Continuous or preset timer operation
  • Optional RS232 port for data transfer
  • Built-in magnetic stirrer for temperature uniformity
  • Digital, up to 99 minutes
  • Immersion heater with relay control
  • Electro-mechanical automatic lift
  • 1000 ml standard
  • IP, BP, USP standards

Tablet Disintegration Test Apparatus Product Specifications

  • Tablet Disintegration Test Apparatus
  • Stainless Steel (SS 304/316), Acrylic Bath
  • 0.5 C (temperature), 1 sec (timer) C
  • Heater, glass beaker, basket assembly, motor, timer, temperature controller
  • TDA-01
  • Approx. 400 x 300 x 350 mm Millimeter (mm)
  • 2 baskets (simultaneous test) or 6 tubes per basket Pcs/hr
  • 50 Hz Hertz (HZ)
  • Pharmaceutical laboratory, tablet disintegration testing
  • Approx. 20 kg Kilograms (kg)
  • Electric
  • Ambient to 45 C ( 0.5 C) Celsius (oC)
  • Digital LED display
  • 0-60 minutes (timer)
  • 230V AC Teraampere (TA)
  • Automatic timer, digital controls, overheat protection
  • Semi-automatic
  • Single or dual station configuration available
  • Operating temperature 1040C, non-condensing
  • Continuous or preset timer operation
  • Optional RS232 port for data transfer
  • Built-in magnetic stirrer for temperature uniformity
  • Digital, up to 99 minutes
  • Immersion heater with relay control
  • Electro-mechanical automatic lift
  • 1000 ml standard
  • IP, BP, USP standards

Tablet Disintegration Test Apparatus Trade Information

  • 1 Week

Product Description

Model : TDTCal100 | Make : ANALAB | HSN Code : 90318000

Technical Specification

  • Stroke Length : 55mm 2mm
  • Number of Stroke Frequency Rate : 2932 Cycles Per Min.
  • Readable Temperature Range : 10.0C to 50.0C
  • Temperature Control Range : 30.0C to 40.0C
  • Temperature Accuracy : 0.2C
  • Temperature Resolution : 0.1C
  • Programmable Timer : 1 sec. to 9 hrs.: 59 min.: 59 sec.
  • Heating time to 37C : Less than 20 min.
  • Heating Technology : Bathless
  • Heater Capacity : DC Heater-150 Watt
  • Heating : Bathless heating results into fast heating and save water
  • Temperature Sensor : PT-100
  • Number of Beaker : Two Capacity 1000 ml
  • Number of Motor : Two
  • Number of Timer : Two
  • Number of Basket : Two (Six Test Tube Per Basket)
  • Control of Basket : Independent Motor & Timer for Two Basket
  • Display : 40 x 4 Line Alphanumeric Backlit LCD
  • Loading of Basket : Magnetised for ease of cleaning
  • Illumination : White Light for better visibility of dis-integration process
  • Parking of Basket : Automatic after completion of test
  • Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
  • Pharmacopeia Complies : As per USP, IP, Ph. Eur.
  • Method : 40 analysis method with View, Print & Delete facility
  • Date : 12/24 Hours Format
  • Time : Real time clock
  • Searching of data : With record number, batch number, Date and by scrolling
  • Report Formation : As per GLP Compliance
  • Analysis Data Storage : More than 750 data can be store in non-Volatile Memory which can print & view company name, print date and time, analysis date & time, record number, batch number / ID, sample name, username, pharmacopeia, assigned method number, analysis done on, model number, serial number, instrument ID, individual dis-integration time of each sample when you did visually detect the dis-integration of the tested sample by simply pushing the relevant character key (1-6), Basket Set & Actual Temperature, Media Used, etc. Secondly, data can print online without saving analysis data in the instrument.
  • 21 CFR Part-11 Compliance :
    In-built with system for ease of operation without PC.
    2 Admin, 10 Reviewers, 40 Users & 1 Manufacturer with individual Login ID & Passcode.
    Audit trail can store more than 5000 lines in instrument.
    Audit trail includes action taken, date & time, action taken by whom.
    Audit trail can be transfer to PC through ANALABsafe software and can print on 40 / 80 column dot matrix printer for record.
    Admins can set up operation permission of each Users & Reviewers.
    Strict Admins control to audit and monitor usage and access.
    Audit trail record can be printed with Date, Date Range and by individual Users ID.
    Once Audit trail transfer to the PC or Printer, system will delete Audit trail records and before final deletion, the system will give warning twice.
    Data integrity with database capability to store Analysis Data, Calibration Data, Calibration and Analysis Method, Audit trail and Passcode in instrument.
    No direct access to data from outside the instrument, thereby creating a closed system.
    Audit traceability to ensure that the device and results are appropriately handled.
    Auto Users logout after defined Logout time.
    Auto Users & Reviewers block when password is entered incorrectly 3 consecutive times
  • Printer Interface : Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer must procure optionally)
  • PC Interface : USB Type - B
  • PC Connectivity : By USB Interface Cable with Driver, ANALABsafe software to transfer Analysis data in GLP format, Calibration data and Audit trail from Instrument to PC in non-editable format (Cannot Delete)
  • Power Supply : 230VAC 10%, 50 Hz
  • Dimensions : 460 x 450 x 710 mm (L x W x H)
  • Weight : 24.5 Kgs (Net) & 29.0 Kgs (Gross)
Precise Temperature & Timing Control

This apparatus features an immersion heater with digital relay control to ensure uniform heating, supported by a built-in magnetic stirrer for consistent temperature throughout the beaker. The digital programmable timer allows settings up to 99 minutes, with accuracy within 1 second, helping users obtain reliable and reproducible results for every test cycle.


Flexible Station & Basket Design

Available in single or dual station configurations, the apparatus accommodates either 2 baskets or 6 tubes per basket, offering versatility for varying disintegration test requirements. Electro-mechanical automatic basket lifts ensure hands-free, standardized operation for efficient testing and minimal manual intervention.


Compliance & Safety Assured

Fully compliant with IP, BP, and USP pharmacopoeial guidelines, the TDA-01 ensures your lab meets regulatory requirements. The apparatus incorporates safety features such as overheat protection, robust SS construction, programmable timer, and user-friendly digital controls for optimum performance and laboratory safety.

FAQs of Tablet Disintegration Test Apparatus:


Q: How does the tablet disintegration test apparatus ensure uniform temperature during testing?

A: The apparatus uses an immersion heater controlled by a relay and incorporates a built-in magnetic stirrer to circulate water, ensuring even temperature distribution across all stations and beakers during operation.

Q: What is the process for running a tablet disintegration test on this apparatus?

A: To perform a test, fill the standard 1000 ml glass beaker with the required medium, place tablets in the test tubes inside the baskets, set the desired temperature and timer using the digital controls, and start the test. The electro-mechanical basket lift automatically handles immersion and removal of baskets.

Q: When should the apparatuss programmable timer be used, and what is its range?

A: The programmable digital timer should be set before initiating a test to match the required disintegration time for your tablets. It can be set from 0 up to 99 minutes with an accuracy of 1 second, providing flexibility for different testing protocols.

Q: Where can the TDA-01 Tablet Disintegration Test Apparatus be effectively utilized?

A: This model is specifically designed for pharmaceutical laboratories, whether in production quality control, research, or academic settings, providing reliable compliance and versatile operation for a variety of tablet formulations.

Q: What are the main benefits of the electro-mechanical automatic basket lift mechanism?

A: The automatic basket lift mechanism simplifies the testing process by ensuring consistent immersion and withdrawal of the baskets, reducing manual intervention, enhancing operational efficiency, and delivering more reproducible results.

Q: How does the apparatus comply with international pharmacopoeia standards?

A: The apparatus is built to meet IP, BP, and USP standards, featuring accurate timing, reliable temperature control, and appropriate materials, ensuring validated and standardized testing procedures in compliance with global pharmaceutical guidelines.

Q: What are the unique features that make this apparatus user-friendly and safe?

A: User-friendly features include a digital LED display, automatic timer, preset and continuous operation modes, overheat protection, and an optional RS232 port for data transfer, all integrated in a compact and durable stainless steel and acrylic housing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Tablet Tesing Instrument - Tablet Dis-integration' category