Back to top
Automatic Programmable Melting Point Apparatus (21 CFR Part-11 Compliance) - Model : ThermoCal100

Automatic Programmable Melting Point Apparatus (21 CFR Part-11 Compliance) - Model : ThermoCal100

426600 INR/Number

Product Details:

  • Frequency 50/60 Hz
  • Core Components High-resolution digital camera, precision heating block, microcontroller, touch interface
  • Feature 21 CFR Part 11 Compliance, USB & network data export, programmable operation
  • Power Source AC mains powered
  • Model No ThermoCal100
  • Capacity Simultaneous determination of 3 samples
  • Voltage 230V AC
  • Click to View more
X

Automatic Programmable Melting Point Apparatus (21 CFR Part-11 Compliance) - Model : ThermoCal100 Price And Quantity

  • 426600 INR/Number
  • 1 Number
  • 10°C to 35°C, non-condensing
  • Automatic optical detection for accurate end-point determination
  • 21 CFR Part-11 electronic records and signatures
  • USB port for data export, integrated printer support
  • Integrated magnifying lens for sample observation
  • User-selectable from 0.1°C/min to 10°C/min
  • High-definition digital camera for real-time and recorded viewing
  • Stores up to 200 user-defined methods
  • Multi-point user calibration with certified reference standards
  • Over-temperature protection and error alarms
  • Simultaneous analysis of up to 3 capillaries

Automatic Programmable Melting Point Apparatus (21 CFR Part-11 Compliance) - Model : ThermoCal100 Product Specifications

  • 410 mm x 320 mm x 290 mm
  • ~12 kg
  • 1C to 400C
  • Fully Automatic
  • 230V AC
  • Room temperature to 400C
  • Accurate determination of solid sample melting point in pharmaceutical and chemical laboratories
  • 0.2C
  • AC mains powered
  • ThermoCal100
  • Simultaneous determination of 3 samples
  • 7-inch TFT Color Touch Screen
  • 50/60 Hz
  • Powder-coated corrosion resistant metal body, heat-resistant glass
  • High-resolution digital camera, precision heating block, microcontroller, touch interface
  • Automatic Programmable Melting Point Apparatus
  • 21 CFR Part 11 Compliance, USB & network data export, programmable operation
  • 10°C to 35°C, non-condensing
  • Automatic optical detection for accurate end-point determination
  • 21 CFR Part-11 electronic records and signatures
  • USB port for data export, integrated printer support
  • Integrated magnifying lens for sample observation
  • User-selectable from 0.1°C/min to 10°C/min
  • High-definition digital camera for real-time and recorded viewing
  • Stores up to 200 user-defined methods
  • Multi-point user calibration with certified reference standards
  • Over-temperature protection and error alarms
  • Simultaneous analysis of up to 3 capillaries

Product Description



Experience the sublime precision of the ThermoCal100 Automatic Programmable Melting Point Apparatus, now on exclusive sale and highly recommended for pharmaceutical and chemical laboratories. This commanding device features 21 CFR Part-11 compliance, ensuring secure electronic records and signatures. Simultaneously analyze up to 3 samples with its spectacular high-definition camera and integrated magnifying lens, delivering unmatched accuracy in melting point determination. The robust, corrosion-resistant metal body, user-friendly touch interface, and extensive method storage combine for a reliable, fully automatic solution. Export data effortlessly via USB, making ThermoCal100 the premium choice for professionals.

User Guidance, Usage, and Key Advantages

For accurate sample melting point analysis, simply load up to three capillaries into ThermoCal100 and utilize the intuitive 7-inch touch screen to select your method. Its fully automatic process guarantees consistent results with a user-selectable temperature ramp. Designed for heavy laboratory use, ThermoCal100 delivers precise measurements with 0.2C accuracy and advanced safety features. The apparatus streamlines workflow, saves valuable time, and enhances operational efficiency through simultaneous analysis and reliable data output options.


Sample Policy, Availability, and Certification Details

Sample demonstrations of ThermoCal100 are available upon request. Clients may obtain a quotation or estimate after submission of a purchase order. All units are certified for 21 CFR Part-11 compliance, meeting global standards for electronic records and signatures in pharmaceutical labs. As a reputable exporter, manufacturer, and supplier based in India, we provide reliable after-sales support and guarantee superior equipment quality, ensuring a smooth purchase process and verified compliance for every laboratory requirement.


FAQs of Automatic Programmable Melting Point Apparatus (21 CFR Part-11 Compliance) - Model : ThermoCal100:


Q: How does ThermoCal100 ensure precise melting point determination?

A: ThermoCal100 utilizes automatic optical detection with a high-definition camera and integrated magnifying lens, allowing for accurate determination of the sample melting point. Its multi-point user calibration with certified standards further ensures consistent reliability.

Q: What is the process for storing and exporting data?

A: Users can store up to 200 user-defined methods for routine analysis. Data can be exported directly via the USB port or through integrated printer support, ensuring seamless documentation and reporting.

Q: When is ThermoCal100 suitable for laboratory use?

A: ThermoCal100 is ideal for pharmaceutical and chemical laboratories requiring compliant, accurate melting point determination within a temperature range of 1C to 400C. The device operates in environments from 10C to 35C, non-condensing.

Q: Where can I obtain certified samples and demonstrations?

A: Certified sample demonstrations are available upon inquiry. Interested clients may request a quotation or estimate through a purchase order for both sample and equipment acquisition.

Q: What are the benefits of simultaneous sample analysis?

A: Simultaneous analysis of up to three samples maximizes productivity, reduces turnaround time, and improves laboratory workflow, making ThermoCal100 a commanding choice for batch testing and routine quality control.

Q: How is user safety maintained during operation?

A: ThermoCal100 features over-temperature protection and error alarms, ensuring operator safety throughout the analysis process.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Chemical Testing Instruments - Melting/Boiling Poi' category