Product Description
The FlameCal100 Microcontroller Based Flame Photometer delivers astounding performance for sodium and potassium determination, with reproducibility under 1% CV and detection limits as low as 0.2 ppm. This model is celebrated for its flawless calibration system, automatic ignition, and exceptional data security compliant with 21 CFR Part-11. Favorable reviews highlight its excellent linearity, dual-channel measurement, and robust design. If you seek a reliable and scarce analytical instrument, you should purchase the FlameCal100 for precise results in laboratory, clinical, and industrial applications.
Versatile Applications & Remarkable Features
The FlameCal100 Microcontroller Based Flame Photometer is engineered for clinical, analytical, industrial, and educational laboratories. Its outstanding features include simultaneous Na and K analysis, automatic calibration, and user-oriented data security. Additionally, GLP/GMP compliance extends the photometer's reliability across regulated environments. With built-in audit trails, corrosion-resistant construction, and adjustable sample aspiration, FlameCal100 addresses diverse and critical laboratory needs, ensuring precise and secure results regardless of application area.
Swift Delivery, Competitive Pricing & Order Process
Experience one of the lowest prices and fast quotation turnaround with the FlameCal100. Our supply ability caters to bulk and regular orders, ensuring rapid order completion for clients across India and internationally. Sample policy is flexible to meet evaluation needs, making decision-making seamless. Customers can inquire for delivery timeframes and detailed quotations, assuring transparent and efficient procurement of this premium, compliant Flame Photometer.
FAQ's of Microcontroller Based Flame Photometer (21 CFR Part-11 Compliance) - Model : FlameCal100:
Q: How does the FlameCal100 ensure compliance with 21 CFR Part-11 regulations?
A: The FlameCal100 integrates advanced user authentication, password protection, electronic signatures, and comprehensive audit trails, fully supporting data integrity requirements for 21 CFR Part-11 compliance.
Q: What are the main application areas for the Microcontroller Based Flame Photometer?
A: The FlameCal100 is utilized in clinical diagnostics, industrial research, analytical testing, and educational laboratories for precise sodium and potassium measurement.
Q: When can I expect delivery after placing a purchase order?
A: Delivery times depend on order volume and location, but orders are processed promptly to ensure timely completion. Customers will receive a quotation with detailed lead times after inquiry.
Q: Where can the FlameCal100 be installed for best results?
A: This flame photometer is suitable for installation in clinical labs, quality control labs, academic institutions, and industrial settings requiring precise flame photometry.
Q: What process does the FlameCal100 use for calibration and drift correction?
A: FlameCal100 features automatic 2/3/4 point calibration and real-time drift correction, ensuring accurate and reliable measurements over extended operation.
Q: How does the instrument maximize data security and integrity during measurements?
A: The device employs multi-level user authentication, passwords, electronic signatures, and audit trails, providing robust safeguards for data integrity and traceability.