Accuracy
0.5 RPM mg
Capacity
Speed : Variable from 20 to 70 / 100 RPM m3/hr
Dimension (L*W*H)
6 x 33 x 39 cm (L x W x H) Centimeter (cm)
Display Type
20 x 4 Line Alphanumeric Backlit LCD
Equipment Materials
Epoxy Based Powder Coated Metallic Body / GMP Enclosure made up of Stainless Steel
Model No
FTCal100
Power
230VAC Volt (v)
Product Type
Friability
Usage
Pharma
Voltage
230VAC 10%, 50 Hz Volt (v)
Weight
15 Kilograms (kg)
Certifications
ISO
Delivery Time
1 Week
FOB Port
vadodara
Main Domestic Market
All India
Main Export Market(s)
Asia
Packaging Details
Standard Pack
Payment Terms
Cash Advance (CA)
Sample Available
Yes
Supply Ability
10 Per Day

Model : FTCal100 | Make : ANALAB | HSN Code : 90318000

Technical Specifications

  • Speed : Variable from 20 to 70 / 100 RPM
  • Accuracy : 0.5 RPM
  • Timer : Variable from 1 sec. to 9 hrs. 59 min 59 sec.
  • Counter : 1 to 9999 revolutions
  • No. of Drums : Two
  • Pharmacopeia Complies : As per USP, IP, Ph. Eur.
  • Method : 40 analysis method for single friability test with View, Print & Delete facility.
  • Weight Transfer : Possible through RS-232 Port (From Balance to Instrument)
  • Tablet Discharge : Automatic in the Sample tray from drum after completion of analysis.
  • 10 Tilt : With Audio Visual Alert message
  • Calculation of result : Friability in %
  • Calibration : RPM and Count (Automatic)
  • Verification : RPM, Count and Time
  • Power failure detection : Un-interrupted tablet testing after power resume.
  • Display : 20 x 4 Line Alphanumeric Backlit LCD
  • Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
  • Analysis Data Storage : More than 1500 data can be store in non-Volatile Memory which can print & view company name, print date and time, analysis date & time, record number, batch number / ID, sample name, username, pharmacopeia, assigned method number, RPM, tilt status, drum type, set and actual counts, initial and final weight, friability result, analysis done on, model number, drum ID, serial number, instrument ID etc. Secondly, analysis data can be print online.
  • Searching of data : With record number, batch number, Date and by scrolling.
  • Report Formation : As per GLP Compliance
  • 21 CFR Part-11 Compliance :
    In-built with system for ease of operation without PC.
    2 Admin, 10 Reviewers, 40 Users & 1 Manufacturer with individual Login ID & Passcode.
    Audit trail can store more than 5000 lines in instrument.
    Audit trail includes action taken, date & time, action taken by whom.
    Audit trail can be transfer to PC through ANALABsafe software and can print on 40 / 80 column dot matrix printer for record.
    Admins can set up operation permission of each Users & Reviewers.
    Strict Admins control to audit and monitor usage and access.
    Audit trail record can be printed with Date, Date Range and by individual Users ID.
    Once Audit trail transfer to the PC or Printer, system will delete Audit trail records and before final deletion, the system will give warning twice.
    Data integrity with database capability to store Analysis Data, Calibration Data, Calibration and Analysis Method, Audit trail and Passcode in instrument.
    No direct access to data from outside the instrument, thereby creating a closed system.
    Audit traceability to ensure that the device and results are appropriately handled.
    Auto Users logout after defined Logout time.
    Auto Users & Reviewers block when password is entered incorrectly 3 consecutive times
  • Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
  • PC Interface : USB Type B
  • PC Connectivity : By USB Interface Cable with Driver, ANALABsafe software to transfer Analysis data in GLP format, Calibration data and Audit trail from Instrument to PC in non-editable format (Cannot Delete)
  • Power Supply : 230VAC 10%, 50 Hz
  • Dimensions:
    Net Dimension: 36 x 33 x 39 cm (L x W x H)
    Gross Dimension: 48 x 44 x 52 cm (L x W x H)
  • Weight:
    Net Weight: 8.5 kg
    Gross Weight: 15 kg

 

Friability Test Apparatus - Double Drum (21 CFR Part-11 Compliance)
 

More Similar Friability Test Apparatus - Double Drum (21 CFR Part-11 Compliance)

Tablet Disintegration Test Apparatus

Price: 284800.0 INR

/

Number

Minimum Order Quantity : 1 Number

Tablet Disintegration Test Apparatus

Accuracy: 0.5 C (temperature), 1 sec (timer) °C

Automation Grade:Semi-automatic

Capacity:2 baskets (simultaneous test) or 6 tubes per basket Pcs/hr

Core Components:Heater, glass beaker, basket assembly, motor, timer, temperature controller

Dimension (L*W*H):Approx. 400 x 300 x 350 mm Millimeter (mm)

Know More

Model : TDTCal100 | Make : ANALAB | HSN Code : 90318000

Technical Specification

  • Stroke Length : 55mm 2mm
  • Number of Stroke Frequency Rate : 2932 Cycles Per Min.
  • Readable Temperature Range : 10.0C to 50.0C
  • Temperature Control Range : 30.0C to 40.0C
  • Temperature Accuracy : 0.2C
  • Temperature Resolution : 0.1C
  • Programmable Timer : 1 sec. to 9 hrs.: 59 min.: 59 sec.
  • Heating time to 37C : Less than 20 min.
  • Heating Technology : Bathless
  • Heater Capacity : DC Heater-150 Watt
  • Heating : Bathless heating results into fast heating and save water
  • Temperature Sensor : PT-100
  • Number of Beaker : Two Capacity 1000 ml
  • Number of Motor : Two
  • Number of Timer : Two
  • Number of Basket : Two (Six Test Tube Per Basket)
  • Control of Basket : Independent Motor & Timer for Two Basket
  • Display : 40 x 4 Line Alphanumeric Backlit LCD
  • Loading of Basket : Magnetised for ease of cleaning
  • Illumination : White Light for better visibility of dis-integration process
  • Parking of Basket : Automatic after completion of test
  • Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
  • Pharmacopeia Complies : As per USP, IP, Ph. Eur.
  • Method : 40 analysis method with View, Print & Delete facility
  • Date : 12/24 Hours Format
  • Time : Real time clock
  • Searching of data : With record number, batch number, Date and by scrolling
  • Report Formation : As per GLP Compliance
  • Analysis Data Storage : More than 750 data can be store in non-Volatile Memory which can print & view company name, print date and time, analysis date & time, record number, batch number / ID, sample name, username, pharmacopeia, assigned method number, analysis done on, model number, serial number, instrument ID, individual dis-integration time of each sample when you did visually detect the dis-integration of the tested sample by simply pushing the relevant character key (1-6), Basket Set & Actual Temperature, Media Used, etc. Secondly, data can print online without saving analysis data in the instrument.
  • 21 CFR Part-11 Compliance :
    In-built with system for ease of operation without PC.
    2 Admin, 10 Reviewers, 40 Users & 1 Manufacturer with individual Login ID & Passcode.
    Audit trail can store more than 5000 lines in instrument.
    Audit trail includes action taken, date & time, action taken by whom.
    Audit trail can be transfer to PC through ANALABsafe software and can print on 40 / 80 column dot matrix printer for record.
    Admins can set up operation permission of each Users & Reviewers.
    Strict Admins control to audit and monitor usage and access.
    Audit trail record can be printed with Date, Date Range and by individual Users ID.
    Once Audit trail transfer to the PC or Printer, system will delete Audit trail records and before final deletion, the system will give warning twice.
    Data integrity with database capability to store Analysis Data, Calibration Data, Calibration and Analysis Method, Audit trail and Passcode in instrument.
    No direct access to data from outside the instrument, thereby creating a closed system.
    Audit traceability to ensure that the device and results are appropriately handled.
    Auto Users logout after defined Logout time.
    Auto Users & Reviewers block when password is entered incorrectly 3 consecutive times
  • Printer Interface : Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer must procure optionally)
  • PC Interface : USB Type - B
  • PC Connectivity : By USB Interface Cable with Driver, ANALABsafe software to transfer Analysis data in GLP format, Calibration data and Audit trail from Instrument to PC in non-editable format (Cannot Delete)
  • Power Supply : 230VAC 10%, 50 Hz
  • Dimensions : 460 x 450 x 710 mm (L x W x H)
  • Weight : 24.5 Kgs (Net) & 29.0 Kgs (Gross)
Precise Temperature & Timing Control

This apparatus features an immersion heater with digital relay control to ensure uniform heating, supported by a built-in magnetic stirrer for consistent temperature throughout the beaker. The digital programmable timer allows settings up to 99 minutes, with accuracy within 1 second, helping users obtain reliable and reproducible results for every test cycle.


Flexible Station & Basket Design

Available in single or dual station configurations, the apparatus accommodates either 2 baskets or 6 tubes per basket, offering versatility for varying disintegration test requirements. Electro-mechanical automatic basket lifts ensure hands-free, standardized operation for efficient testing and minimal manual intervention.


Compliance & Safety Assured

Fully compliant with IP, BP, and USP pharmacopoeial guidelines, the TDA-01 ensures your lab meets regulatory requirements. The apparatus incorporates safety features such as overheat protection, robust SS construction, programmable timer, and user-friendly digital controls for optimum performance and laboratory safety.

FAQs of Tablet Disintegration Test Apparatus:


Q: How does the tablet disintegration test apparatus ensure uniform temperature during testing?

A: The apparatus uses an immersion heater controlled by a relay and incorporates a built-in magnetic stirrer to circulate water, ensuring even temperature distribution across all stations and beakers during operation.

Q: What is the process for running a tablet disintegration test on this apparatus?

A: To perform a test, fill the standard 1000 ml glass beaker with the required medium, place tablets in the test tubes inside the baskets, set the desired temperature and timer using the digital controls, and start the test. The electro-mechanical basket lift automatically handles immersion and removal of baskets.

Q: When should the apparatuss programmable timer be used, and what is its range?

A: The programmable digital timer should be set before initiating a test to match the required disintegration time for your tablets. It can be set from 0 up to 99 minutes with an accuracy of 1 second, providing flexibility for different testing protocols.

Q: Where can the TDA-01 Tablet Disintegration Test Apparatus be effectively utilized?

A: This model is specifically designed for pharmaceutical laboratories, whether in production quality control, research, or academic settings, providing reliable compliance and versatile operation for a variety of tablet formulations.

Q: What are the main benefits of the electro-mechanical automatic basket lift mechanism?

A: The automatic basket lift mechanism simplifies the testing process by ensuring consistent immersion and withdrawal of the baskets, reducing manual intervention, enhancing operational efficiency, and delivering more reproducible results.

Q: How does the apparatus comply with international pharmacopoeia standards?

A: The apparatus is built to meet IP, BP, and USP standards, featuring accurate timing, reliable temperature control, and appropriate materials, ensuring validated and standardized testing procedures in compliance with global pharmaceutical guidelines.

Q: What are the unique features that make this apparatus user-friendly and safe?

A: User-friendly features include a digital LED display, automatic timer, preset and continuous operation modes, overheat protection, and an optional RS232 port for data transfer, all integrated in a compact and durable stainless steel and acrylic housing.

Microcontroller Based Karl Fischer Titrator - Model : AquaCal50

Price: 132600 INR

/

Number

Minimum Order Quantity : 1 Number

Microcontroller Based Karl Fischer Titrator - Model : AquaCal50

Accuracy:±0.2%

Automation Grade:Semi-Automatic

Capacity:1 ppm to 100% water content

Core Components:Touch keypad, LCD display, burette with magnetic stirrer, electrode, microcontroller

Dimension (L*W*H):275 x 340 x 175 mm

Know More

Microcontroller-Based Karl Fischer Titrator - Model: AquaCal50 measures the quantity of water in a sample. Because the presence of water may alter several properties of a product, such as reactivity, stability, and quality, KF titration is vital and employed in many sectors. The device offers simple instructions that will help you through the titration procedure. Microcontroller-Based Karl Fischer Titrator - Model: AquaCal50 employs cutting-edge microcontroller technology and superior engineering approaches to improve accuracy and repeatability. It employs a very sensitive motorized dispensing mechanism.



Precision and Efficiency

AquaCal50's microcontroller-based architecture offers exceptional accuracy (0.2%) in water content measurement. With variable speed control on the magnetic stirrer, programmable titration parameters, and automatic end-point detection, it ensures both speed and reliability in results-crucial for demanding industrial and laboratory environments.


Versatile Sample Compatibility

Designed for diverse laboratory needs, the AquaCal50 accurately analyzes water content in liquids, powders, granules, oils, pharmaceuticals, chemicals, and petro-products. The robust, chemical-resistant enclosure and user-friendly manual or burette sample entry accommodate a range of sample types and volumes.


User-Friendly Design and Safety

Equipped with a touch keypad, 4-line LCD display, splash-proof enclosure, print interface, and easy recall of the last method and results, the AquaCal50 prioritizes operator convenience. Fused power supply and overload protection ensure steadfast operation and safety in routine use.

FAQ's of Microcontroller Based Karl Fischer Titrator - Model : AquaCal50:


Q: How does the AquaCal50 Karl Fischer Titrator determine the water content in a sample?

A: The instrument utilizes the Karl Fischer titration method, which involves an electrochemical reaction to quantitatively determine water content in the sample. The microcontroller automates the titration process and detects the end-point both visually and audibly, ensuring accurate and reliable results.

Q: What types of samples can be analyzed with the AquaCal50?

A: The AquaCal50 is versatile and can be used to determine water content in liquids, powders, granules, oils, pharmaceuticals, chemicals, and petro-products, making it well-suited for laboratories and industrial applications.

Q: When should user calibration be performed on the instrument?

A: User calibration should be conducted periodically using a standard water solution, especially before critical measurements or whenever accuracy verification is needed. This ensures ongoing compliance with ISO, ASTM, BIS, and pharmacopoeia standards.

Q: Where can results from the AquaCal50 be recorded or exported?

A: Test results and method details can be printed directly via the RS232 port for printer or PC connectivity, allowing for convenient documentation and data management in laboratory or quality control settings.

Q: What is the process for sample introduction into the titrator?

A: Samples can be introduced either manually using a syringe or directly through the 10 ml burette. The magnetic stirrer ensures thorough mixing, and the titration process is guided by programmable parameters and automatic detection.

Q: How does the AquaCal50 benefit laboratory users?

A: The AquaCal50 enhances laboratory productivity by offering fast, precise, and reproducible water content determinations, low reagent consumption, simple operation, and robust safety features, thereby streamlining routine analyses and reducing operational costs.

Microcontroller Based Flame Photometer (21 CFR Part-11 Compliance) - Model : FlameCal100

Price: 236600 INR

/

Number

Minimum Order Quantity : 1 Number

Microcontroller Based Flame Photometer (21 CFR Part-11 Compliance) - Model : FlameCal100

Accuracy:±2% for Na/K

Automation Grade:Automatic

Capacity:Dual channel measurement (Simultaneous Na & K)

Core Components:Flame Photometry Module, Microcontroller Unit, Air Compressor, Nebulizer

Dimension (L*W*H):420 x 380 x 215 mm

Know More



The FlameCal100 Microcontroller Based Flame Photometer delivers astounding performance for sodium and potassium determination, with reproducibility under 1% CV and detection limits as low as 0.2 ppm. This model is celebrated for its flawless calibration system, automatic ignition, and exceptional data security compliant with 21 CFR Part-11. Favorable reviews highlight its excellent linearity, dual-channel measurement, and robust design. If you seek a reliable and scarce analytical instrument, you should purchase the FlameCal100 for precise results in laboratory, clinical, and industrial applications.

Versatile Applications & Remarkable Features

The FlameCal100 Microcontroller Based Flame Photometer is engineered for clinical, analytical, industrial, and educational laboratories. Its outstanding features include simultaneous Na and K analysis, automatic calibration, and user-oriented data security. Additionally, GLP/GMP compliance extends the photometer's reliability across regulated environments. With built-in audit trails, corrosion-resistant construction, and adjustable sample aspiration, FlameCal100 addresses diverse and critical laboratory needs, ensuring precise and secure results regardless of application area.


Swift Delivery, Competitive Pricing & Order Process

Experience one of the lowest prices and fast quotation turnaround with the FlameCal100. Our supply ability caters to bulk and regular orders, ensuring rapid order completion for clients across India and internationally. Sample policy is flexible to meet evaluation needs, making decision-making seamless. Customers can inquire for delivery timeframes and detailed quotations, assuring transparent and efficient procurement of this premium, compliant Flame Photometer.


FAQ's of Microcontroller Based Flame Photometer (21 CFR Part-11 Compliance) - Model : FlameCal100:


Q: How does the FlameCal100 ensure compliance with 21 CFR Part-11 regulations?

A: The FlameCal100 integrates advanced user authentication, password protection, electronic signatures, and comprehensive audit trails, fully supporting data integrity requirements for 21 CFR Part-11 compliance.

Q: What are the main application areas for the Microcontroller Based Flame Photometer?

A: The FlameCal100 is utilized in clinical diagnostics, industrial research, analytical testing, and educational laboratories for precise sodium and potassium measurement.

Q: When can I expect delivery after placing a purchase order?

A: Delivery times depend on order volume and location, but orders are processed promptly to ensure timely completion. Customers will receive a quotation with detailed lead times after inquiry.

Q: Where can the FlameCal100 be installed for best results?

A: This flame photometer is suitable for installation in clinical labs, quality control labs, academic institutions, and industrial settings requiring precise flame photometry.

Q: What process does the FlameCal100 use for calibration and drift correction?

A: FlameCal100 features automatic 2/3/4 point calibration and real-time drift correction, ensuring accurate and reliable measurements over extended operation.

Q: How does the instrument maximize data security and integrity during measurements?

A: The device employs multi-level user authentication, passwords, electronic signatures, and audit trails, providing robust safeguards for data integrity and traceability.

Resistivity Analyzer

Price: 54800.0 INR

/

Number

Minimum Order Quantity : 1 Number

Resistivity Analyzer

Accuracy: 1% of reading °C

Automation Grade:Semi-Automatic

Capacity:2000 counts Kg

Color:White blue

Core Components:Microprocessor, Electrodes, LCD Screen

Know More

Model : ConCal50 | Make : ANALAB | HSN Code : 90278990
  • Resistivity Range : 20.00 M to 50.00 K, 5.00 K, 500.00 , 50.00 , 0.50
  • Resistivity Resolution : 0.001
  • Display : 20 x 4 Line Alphanumeric Backlit LCD.
  • Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS.
  • Calibration Data Storage : Non-Volatile Memory which can store, print & view with calibration date & time, cell constant, calibration range, standard conductivity solution, measured conductivity at 25C, actual temperature, calibration factor, instrument serial number, instrument ID, model number etc.
  • Analysis Data Storage : More than 750 analysis data can be stored with corresponding calibration data with company name, analysis date & time, record number, batch number / ID, sample name, username, conductivity at 25C and conductivity at actual temperature, % Tempco, conductivity to TDS conversion factor, TDS, resistivity, salinity, instrument serial number, instrument ID, model number etc. Secondly, analysis data can be print online without saving analysis.
  • Searching of data : With record number, batch number, Date and by scrolling
  • Report Formation : As per GLP Compliance
  • Password Protection : Date & Time, Calibration Mode, Analysis Mode & Delete Stored Analysis Data.
  • Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
  • Power Supply : DC Adaptor
  • Dimensions:
    Net Dimension: 22 x 21 x 11 cm (L x W x H)
    Gross Dimension: 33 x 30 x 24 cm (L x W x H)
  • Weight:
    Net Weight: 1.5 kg
    Gross Weight: 3.5 kg
Multiparameter Analyzer (pH/ORP/Conductivity/TDS/Resistivity/Salinity/°C) (21 CFR Part-11 Compliance) - Model : MultiCal100

Accuracy:pH: ±0.01 pH, Conductivity: ±1% of reading

Automation Grade:Semi-Automatic/Automatic Calibration

Capacity:Multi-parameter (Simultaneous measurement of pH/ORP, Conductivity, TDS, Resistivity, Salinity, Temperature)

Core Components:Microprocessor Controller, Sensor Inputs, Signal Processing Module, LCD Display

Dimension (L*W*H):230 x 200 x 90 mm

Know More



Unlock top-drawer water analysis precision with the venerable MultiCal100 Multi-Parameter Analyzer. Designed for laboratories and industrial sites, this benchtop/panel-mount device simultaneously measures pH, ORP, Conductivity, TDS, Resistivity, Salinity, and Temperature with optimum accuracy. Benefit from 21 CFR Part 11 compliance, robust audit trails, multi-channel input, and automated calibration. Its large backlit LCD, real-time data output, and extensive memory (up to 1,000,000 records) streamline monitoring. Secure your data with advanced password protection. Instant Checkout available-grab yours and elevate your workflow today!

Seamless Operation & Standout Features

The MultiCal100 excels in user direction with an intuitive interface, multi-language support, and automatic calibration. Operators can manage up to four electrodes at once, view multiple parameters simultaneously, and respond swiftly with configurable alarms. Its extra features-such as real-time data logging, advanced connectivity, and robust IP65 housing-deliver a competitive edge. Adhering strictly to GLP/GMP and 21 CFR Part 11 requirements, the analyzer provides premium reliability and security for regulated environments.


Payment Terms, Export Charge, and Delivery Information

Payment terms for the MultiCal100 are flexible to support your needs, ensuring a smooth purchasing experience within the main domestic market and for export markets. Charges are transparent, with no hidden fees. Fast delivery is a priority-expect your analyzer to be shipped promptly, minimizing downtime in your operations. As an exporter, manufacturer, and supplier from India, we guarantee secure logistics and timely tracking for each order.


FAQ's of Multiparameter Analyzer (pH/ORP/Conductivity/TDS/Resistivity/Salinity/AC) (21 CFR Part-11 Compliance) - Model : MultiCal100:


Q: How does the MultiCal100 ensure data integrity and security?

A: The MultiCal100 is fully compliant with 21 CFR Part 11, providing electronic records, e-signature capability, multi-level password protection, and audit trails to safeguard data integrity and security.

Q: What parameters can the MultiCal100 measure simultaneously?

A: The MultiCal100 can simultaneously measure pH, ORP, Conductivity, TDS, Resistivity, Salinity, and Temperature, making it an all-in-one solution for comprehensive water quality analysis.

Q: Where can the MultiCal100 be installed and used?

A: With its IP65-rated enclosure and flexible mounting accessories, the MultiCal100 can be wall-mounted or panel-mounted in both laboratory and industrial environments, adapting to diverse operational demands.

Q: What is the process for exporting the MultiCal100 to international markets?

A: As a leading exporter and manufacturer in India, we offer clear export processes. Customers can place orders, select payment methods, and rely on our secure, efficient logistics for timely delivery worldwide.

Q: When is it necessary to recalibrate the MultiCal100 analyzer?

A: Calibration can be performed automatically using multi-point calibration routines or manually as needed, depending on frequency of use and regulatory requirements for your application.

Q: What are the benefits of data logging and real-time report generation with this analyzer?

A: Data logging stores up to 1,000,000 records and 5000 calibration records, while real-time report generation ensures compliance and instant access to vital analysis information, enhancing workflow efficiency.

Karl Fischer Titration

Accuracy:±0.01% moisture detection

Automation Grade:Semi Automatic

Capacity:Sample 1 mg – 100 g

Core Components:Burette, Electrode, Stirrer, Reagent Bottle

Dimension (L*W*H):350 x 275 x 175 mm

Know More

Owing to our proficiency in this domain, we are affianced in offering high quality range of Karl Fischer Titration. Manufactured by our adroit experts using high quality materials and the advanced technology as per the industry standards, this is strictly examined on different parameters. Furthermore, this Karl Fischer Titrationis ideal for determining the trace amounts of water in a sample.

Features:

  • Unmatched performance
  • Long service life
  • Robust in construction

Accessories

  • 250ml Reaction Vessel

  • Dual Platinum Electrode

  • PTFE Paddle PTFE Assembly

  • Moisture Trap for Reaction Vessel & 250ml Amber Reservoir Bottle

  • Dispensing Tube (02 Nos)

  • PTFE Tubing for Dispensing Path

  • Operational & Instruction Manual

  • Manufacturer Test Certificate and Warranty Card.

Technical Specification

  • Method of Detection :Conductometric

  • Backlit LCD Display :20 x 4 Line Alphanumeric

  • Range of Moisture Detection : Less than 10 PPM to 100%

  • Display of Reading :Direct Reading of Moisture in PPM, Percentage(%) & mg/ml of water

  • Dispenser :Motorized Dispensing for low and accurate measurement of reagent.

  • Electrode :Dual Platinum Electrode.

  • Interface :Serial & Parallel Port for PC & Dot-matrix Printer attachment.

  • Stirring Time :00:00 to 99:00 (Minutes : Second) - Users Adjustable

  • End Point Time :1-99 Seconds , Users Adjustable

  • End Point Sensitivity of Moisture Detection :Users Adjustable

  • Calibration Reminder Alarm :0-99 hours

  • Data Storage :More than 100 Analysis data with corresponding calibration data.

  • Input :Electrode Connector

  • Power supply :230 VAC + 10%, 50 Hz




Versatile Moisture Analysis

With a measurement range from 1 ppm to 100% moisture, the Karl Fischer Titration Apparatus accommodates a wide array of sample types, from minute pharmaceutical powders to larger food and chemical samples. This versatility makes it ideal for industries demanding high-precision moisture content assessment.


User-Friendly Digital Interface

The apparatus boasts a clear digital LCD display and incorporates auto end detection for enhanced convenience and reduced user error. Moisture range programming further streamlines the titration process, allowing users to customize parameters according to specific testing requirements.


Robust Construction, Reliable Performance

Crafted from stainless steel and protected with a powder-coated body, the system is both durable and easy to maintain. Its core componentsburette, electrode, stirrer, and reagent bottleare engineered for superior accuracy even in frequent-use environments.

FAQs of Karl Fischer Titration:


Q: How does the Karl Fischer Titration Apparatus determine moisture content in samples?

A: The KF 101 uses the Karl Fischer titration methoda chemical process tailored to accurately measure water content in various substances. This is achieved by introducing Karl Fischer reagent to the sample, and the end point is automatically detected, ensuring precise results.

Q: What is the capacity range for sample sizes that this apparatus can measure?

A: This model can handle sample weights from as low as 1 mg up to 100 g, making it suitable for both low- and high-volume laboratory applications.

Q: When is it recommended to use the Karl Fischer Titration Apparatus?

A: This apparatus is used whenever accurate moisture analysis is essential, such as during quality control, raw material testing, and production monitoring across pharmaceutical, chemical, food, and related industries.

Q: Where can this apparatus be used and what power source does it require?

A: It is suitable for laboratory settings in industrial, academic, or research institutions. The apparatus operates on 230V AC mains and is designed to function within a temperature range of 5C to 45C.

Q: What key components are included in the system and what role do they play?

A: Major components include a burette (for titrant dispensing), an electrode (for endpoint detection), a stirrer (for sample homogenization), and a reagent bottle. Together, they ensure accurate, reliable, and repeatable titration results.

Q: How does the auto end detection feature benefit the user?

A: Auto end detection automatically identifies the titration endpoint, streamlining the process, minimizing human error, and improving result accuracy and consistency.

Q: What is the accuracy of the KF 101 and what does this mean for users?

A: The apparatus boasts an accuracy of 0.01% moisture detection, meaning users can trust its results even where minimal moisture levels must be precisely quantified, ensuring product quality and regulatory compliance.

Share a Quick Message with us
Enter Buying Requirement Details

Requirment is not provided for the inquiry

Mobile number

Mobile no is not provided for the inquiry

Email

Email is not provided for the inquiry

call Send Inquiry whatsapp

WhatsApp

Get Latest Price

 
close
Tell us about your requirement
product

Price: Â

Quantity
Select Unit

  • 50
  • 100
  • 150
  • 200
  • 250
  • 300
Additional detail
Mobile number

Email